Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.336
Filtrar
1.
BMC Microbiol ; 24(1): 143, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664628

RESUMEN

BACKGROUND: Broiler chickens are frequently colonized with Extended-Spectrum Beta-Lactamase- (ESBL-) and plasmid mediated AmpC Beta-Lactamase- (pAmpC-) producing Enterobacterales, and we are confronted with the potential spread of these resistant bacteria in the food chain, in the environment, and to humans. Research focused on identifying of transmission routes and investigating potential intervention measures against ESBL- and pAmpC- producing bacteria in the broiler production chain. However, few data are available on the effects of cleaning and disinfection (C&D) procedures in broiler stables on ESBL- and pAmpC- producing bacteria. RESULTS: We systematically investigated five broiler stables before and after C&D and identified potential ESBL- and pAmpC- colonization sites after C&D in the broiler stables, including the anteroom and the nearby surrounding environment of the broiler stables. Phenotypically resistant E. coli isolates grown on MacConkey agar with cefotaxime were further analyzed for their beta-lactam resistance genes and phylogenetic groups, as well as the relation of isolates from the investigated stables before and after C&D by whole genome sequencing. Survival of ESBL- and pAmpC- producing E. coli is highly likely at sites where C&D was not performed or where insufficient cleaning was performed prior to disinfection. For the first time, we showed highly related ESBL-/pAmpC- producing E. coli isolates detected before and after C&D in four of five broiler stables examined with cgMLST. Survival of resistant isolates in investigated broiler stables as well as transmission of resistant isolates from broiler stables to the anteroom and surrounding environment and between broiler farms was shown. In addition, enterococci (frequently utilized to detect fecal contamination and for C&D control) can be used as an indicator bacterium for the detection of ESBL-/pAmpC- E. coli after C&D. CONCLUSION: We conclude that C&D can reduce ESBL-/pAmpC- producing E. coli in conventional broiler stables, but complete ESBL- and pAmpC- elimination does not seem to be possible in practice as several factors influence the C&D outcome (e.g. broiler stable condition, ESBL-/pAmpC- status prior to C&D, C&D procedures used, and biosecurity measures on the farm). A multifactorial approach, combining various hygiene- and management measures, is needed to reduce ESBL-/pAmpC- E. coli in broiler farms.


Asunto(s)
Proteínas Bacterianas , Pollos , Desinfección , Escherichia coli , Granjas , beta-Lactamasas , Animales , beta-Lactamasas/genética , beta-Lactamasas/metabolismo , Pollos/microbiología , Escherichia coli/genética , Escherichia coli/efectos de los fármacos , Escherichia coli/aislamiento & purificación , Desinfección/métodos , Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Infecciones por Escherichia coli/veterinaria , Infecciones por Escherichia coli/microbiología , Infecciones por Escherichia coli/transmisión , Enfermedades de las Aves de Corral/microbiología , Enfermedades de las Aves de Corral/prevención & control , Antibacterianos/farmacología , Filogenia , Plásmidos/genética , Tipificación de Secuencias Multilocus , Secuenciación Completa del Genoma
2.
World J Urol ; 42(1): 252, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652324

RESUMEN

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Asunto(s)
Antiinfecciosos Locales , Desinfección , Povidona Yodada , Próstata , Recto , Humanos , Povidona Yodada/uso terapéutico , Povidona Yodada/administración & dosificación , Masculino , Desinfección/métodos , Antiinfecciosos Locales/uso terapéutico , Antiinfecciosos Locales/administración & dosificación , Próstata/patología , Profilaxis Antibiótica/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/patología
3.
Environ Sci Technol ; 58(15): 6552-6563, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38571383

RESUMEN

Extracellular polymeric substances (EPS) ubiquitously encapsulate microbes and play crucial roles in various environmental processes. However, understanding their complex interactions with dynamic bacterial behaviors, especially during the disinfection process, remains very limited. In this work, we investigated the impact of EPS on bacterial disinfection kinetics by developing a permanent EPS removal strategy. We genetically disrupted the synthesis of exopolysaccharides, the structural components of EPS, in Pseudomonas aeruginosa, a well-known EPS-producing opportunistic pathogen found in diverse environments, creating an EPS-deficient strain. This method ensured a lasting absence of EPS while maintaining bacterial integrity and viability, allowing for real-time in situ investigations of the roles of EPS in disinfection. Our findings indicate that removing EPS from bacteria substantially lowered their susceptibility threshold to disinfectants such as ozone, chloramine B, and free chlorine. This removal also substantially accelerated disinfection kinetics, shortened the resistance time, and increased disinfection efficiency, thereby enhancing the overall bactericidal effect. The absence of EPS was found to enhance bacterial motility and increase bacterial cell vulnerability to disinfectants, resulting in greater membrane damage and intensified reactive oxygen species (ROS) production upon exposure to disinfectants. These insights highlight the central role of EPS in bacterial defenses and offer promising implications for developing more effective disinfection strategies.


Asunto(s)
Desinfectantes , Desinfección , Desinfección/métodos , Matriz Extracelular de Sustancias Poliméricas , Desinfectantes/farmacología , Cloro/farmacología , Cinética
4.
J Appl Microbiol ; 135(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38573833

RESUMEN

In the 1940s and 1950s, researchers seeking safe and novel ways to eliminate airborne pathogens from enclosed spaces, investigated glycol vapours as a method of disinfection. More recently, the COVID-19 pandemic highlighted the need for a non-toxic aerial disinfectant that can be used in the presence of people. This scoping review is intended to analyse the early and more recent literature on glycol disinfection, scrutinizing the methodologies used, and to determine if the use of glycols as modern-day disinfectants is justified PRISMA-ScR guidelines were used to assess the 749 articles retrieved from the Web of Science platform, with 46 articles retained after the search strategy was applied. Early studies generally demonstrated good disinfection capabilities against airborne bacteria and viruses, particularly with propylene glycol (PG) vapour. Vapour pressure, relative humidity, and glycol concentration were found to be important factors affecting the efficacy of glycol vapours. Contact times depended mainly on the glycol application method (i.e. aerosolization or liquid formulation), although information on how glycol efficacy is impacted by contact time is limited. Triethylene glycol (TEG) is deemed to have low toxicity, carcinogenicity, and mutagenicity and is registered for use in air sanitization and deodorization by the US Environmental Protection Agency. Glycols are also used in liquid formulations for their antimicrobial activity against a wide range of microorganisms, although when used as a non-active excipient in products, their contribution to antimicrobial efficacy is rarely assessed. The appropriate use of liquid glycol-containing formulations was found to positively impact the antimicrobial capabilities of disinfectants when used at temperatures <0, food preservatives, and dental medicaments. Providing modern delivery technology can accurately control environmental conditions, the use of aerosolized glycol formulations should lead to successful disinfection, aiding infection prevention, and control regimens.


Asunto(s)
Antiinfecciosos , Desinfectantes , Humanos , Pandemias/prevención & control , Desinfectantes/farmacología , Desinfección/métodos , Antiinfecciosos/farmacología , Propilenglicol/farmacología , Gases
5.
Food Microbiol ; 121: 104516, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38637078

RESUMEN

Oxidation-reduction potential (ORP) is commonly used as a rapid measurement of the antimicrobial potential of free chlorine during industrial fresh produce washing. The current study tested the hypothesis that ORP can act as a "single variable" measurement of bacterial (vegetative and endospores) inactivation effectiveness with free chlorine irrespective of the water pH value. This situation has on occasion been assumed but never confirmed nor disproven. Chlorine-dosed pH 6.5 and 8.5 phosphate buffer solutions were inoculated with Escherichia coli (E. coli), Listeria innocua (L. innocua), or Bacillus subtilis (B. subtilis) endospores. ORP, free chlorine (FC), and log reduction were monitored after 5 s (for E. coli and L. innocua) and up to 30 min (for B. subtilis spores) of disinfection. Logistic and exponential models were developed to describe how bacteria reduction varied as a function of ORP at different pH levels. Validation tests were performed in phosphate buffered pH 6.5 and 8.5 cabbage wash water periodically dosed with FC, cabbage extract and a cocktail of Escherichia coli O157:H7 (E. coli O157:H7) and Listeria monocytogenes (L. monocytogenes). The built logistic and exponential models confirmed that at equal ORP values, the inactivation of the surrogate strains was not consistent across pH 6.5 and pH 8.5, with higher reductions at higher pH. This is the opposite of the well-known free chlorine-controlled bacterial inactivation, where the antibacterial effect is higher at lower pH. The validation test results indicated that in the cabbage wash water, the relationship between disinfection efficiency and ORP was consistent with the oxidant demand free systems. The study suggests that ORP cannot serve as a reliable single variable measurement to predict bacterial disinfection in buffered systems. When using ORP to monitor and control the antibacterial effectiveness of the chlorinated wash water, it is crucial to take into account (and control) the pH.


Asunto(s)
Escherichia coli O157 , Listeria monocytogenes , Listeria , Desinfección/métodos , Cloro/farmacología , Cloro/análisis , Contaminación de Alimentos/análisis , Microbiología de Alimentos , Oxidantes , Recuento de Colonia Microbiana , Manipulación de Alimentos/métodos , Cloruros , Oxidación-Reducción , Agua/química , Antibacterianos , Concentración de Iones de Hidrógeno , Fosfatos
6.
Food Microbiol ; 121: 104523, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38637085

RESUMEN

This study investigated the fungicidal efficiency and mechanism of action of dielectric barrier discharge cold atmosphere plasma (DBD-CAP) in inactivating Aspergillus niger (A. niger) spores. The disinfection efficacy and quality of dried jujube used as the processing application object were also studied. The results indicated that the Weibull + Tail model performed better for spore inactivation curves at different voltages among various treatment times, and the spore cells were reduced by 4.05 log (cfu/mL) in spores suspension at 70 kV after 15 min of treatment. This disinfection impact was further supported by scanning electron microscope (SEM) and transmission electron microscopy (TEM) images, which showed that the integrity of the cell membrane was damaged, and the intracellular content leaked out after DBD-CAP treatment. Elevated levels of reactive oxygen species (ROS) during the treatment increased the relative conductivity of cells, and leakage of nucleic acids and proteins further supported the disinfection impact. Additionally, the growth and toxicity of surviving A. niger spores after treatment were also greatly reduced. When DBD-CAP was applied to disinfecting dried jujube, the spore number exhibited a 2.67 log cfu/g reduction after treatment without significant damage observed onto the quality (P > 0.05).


Asunto(s)
Aspergillus , Gases em Plasma , Ziziphus , Aspergillus niger , Gases em Plasma/farmacología , Desinfección/métodos
7.
PLoS One ; 19(4): e0300355, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38573892

RESUMEN

In recent decades, minimally invasive surgery has become the favoured surgical technique, with increasing utilisation of robotic surgery to enhance patient outcomes. However, the design complexity of surgical robotic instruments can pose challenges in maintaining adequate cleaning, disinfection and sterilisation-particularly of the device's interior. In our hospital, robotic instruments are reused for a maximum of ten successive patients, following the manufacturer's guidelines. To the best of our knowledge, neither the manufacturer nor ISO standards have specified any methods to determine the sterility of robotic instruments after cleaning, disinfection and sterilisation procedures. In a small pilot study, we used a locally developed protocol to evaluate the sterility of 20 da Vinci SI robotic instruments, with the aim of determining whether the recommended cleaning, disinfection and sterilisation process is adequate to achieve safe usage in subsequent patients. None of the 20 instruments showed viable micro-organisms, therefore the robotic instruments were considered sterile, and suitable for re-use. We recommend our protocol to other hospitals, to be used as an essential control element in the assessment of their unique reprocessing technique for robotic instruments.


Asunto(s)
Infertilidad , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Proyectos Piloto , Desinfección/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos
8.
Oral Health Prev Dent ; 22: 151-158, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652288

RESUMEN

PURPOSE: To investigate the effect of full-mouth disinfection on the sizes of the periodontal wound and periodontal inflammatory burden and whether it leads to a decrease in C-reactive protein (CRP) levels. MATERIALS AND METHODS: The study included 20 systemically healthy subjects (11 women and 9 men) 30 to 68 years old with localised or generalised periodontitis (stage III, grade C). The sizes of the periodontal wound and periodontal inflammatory burden were measured with the web application "Periodontalwound", which is based on measurements of average tooth cervices, as well as probing depths and bleeding on probing assessed at six sites around each tooth present in the oral cavity. The levels of hsCRP (high-sensitivity CRP) were measured with an immunochemical method. All three parameters were measured before initial treatment and 3 months after therapy. Full-mouth disinfection included removal of plaque and calculus with ultrasonic and hand instruments in one session. RESULTS: The results showed a statistically significant decrease in the size of the periodontal wound (p < 0.001), a statistically significant decrease in the size of periodontal inflammatory burden (p < 0.001), and a decrease in hsCRP levels 3 months after therapy. CONCLUSION: Full-mouth disinfection leads to a decrease in the periodontal wound and periodontal inflammatory burden size, as well as a decrease in the levels of hsCRP in patients with localised or generalised periodontitis (stage III, grade C).


Asunto(s)
Proteína C-Reactiva , Desinfección , Humanos , Masculino , Femenino , Proteína C-Reactiva/análisis , Persona de Mediana Edad , Adulto , Anciano , Desinfección/métodos , Periodontitis , Índice Periodontal , Placa Dental , Cálculos Dentales , Bolsa Periodontal , Terapia por Ultrasonido/métodos
9.
J Hazard Mater ; 470: 134254, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38615644

RESUMEN

The existence of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) has been a global public environment and health issue. Due to the different cell structures, gram-positive/negative ARB exhibit various inactivation mechanisms in water disinfection. In this study, a gram-negative ARB Escherichia coli DH5α (E. coli DH5α) was used as a horizontal gene transfer (HGT) donor, while a gram-positive ARB Bacillus as a recipient. To develop an efficient and engineering applicable method in water disinfection, ARB and ARGs removal efficiency of Fe(VI) coupled peroxydisulfate (PDS) or peroxymonosulfate (PMS) was compared, wherein hydroxylamine (HA) was added as a reducing agent. The results indicated that Fe(VI)/PMS/HA showed higher disinfection efficiency than Fe(VI)/PDS/HA. When the concentration of each Fe(VI), PMS, HA was 0.48 mM, 5.15 log E. coli DH5α and 3.57 log Bacillus lost cultivability, while the proportion of recovered cells was 0.0017 % and 0.0566 %, respectively, and HGT was blocked. Intracellular tetA was reduced by 2.49 log. Fe(IV) and/or Fe(V) were proved to be the decisive reactive species. Due to the superiority of low cost as well as high efficiency and practicality, Fe(VI)/PMS/HA has significant application potential in ARB, ARGs removal and HGT inhibition, offering a new insight for wastewater treatment.


Asunto(s)
Transferencia de Gen Horizontal , Hierro , Peróxidos , Peróxidos/química , Hierro/química , Purificación del Agua/métodos , Escherichia coli/efectos de los fármacos , Escherichia coli/genética , Farmacorresistencia Bacteriana/genética , Desinfección/métodos , Sulfatos/química , Antibacterianos/farmacología , Antibacterianos/química , Bacillus/genética , Bacillus/efectos de los fármacos , Bacillus/metabolismo
10.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622548

RESUMEN

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Asunto(s)
Desinfectantes , Desinfección , Humanos , Desinfección/métodos , Glutaral , Hipoclorito de Sodio , Materiales de Impresión Dental , Técnica de Impresión Dental
11.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38608912

RESUMEN

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Asunto(s)
Desinfección , Agua Potable , Purificación del Agua , Agua Potable/microbiología , Agua Potable/química , Desinfección/métodos , Purificación del Agua/métodos , Microbiología del Agua , Abastecimiento de Agua
12.
PLoS One ; 19(4): e0302258, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38626152

RESUMEN

Effective surface disinfection is crucial for preventing the spread of pathogens in hospitals. Standard UltraViolet-C (UV-C) lamps have been widely used for this purpose, but their disinfection efficiency under real-world conditions is not well understood. To fill this gap, the influence of the power of the ultraviolet radiator, source-sample distance, and exposure time on the performance of UV-C lamps against Escherichia coli and Staphylococcus epidermidis were experimentally determined in the laboratory and hospital. The obtained results showed that the UV irradiance and, thus, the UV-C disinfection efficiency decreased significantly at distances greater than 100 cm from the UV-C lamp. Moreover, increasing the total power of the radiators does not improve the performance of UV-C lamps under real conditions. The UV-C disinfection efficiency greater than 90% was achieved only under laboratory conditions at a close distance from the UV-C lamp, i.e., 10 cm. These findings provide novel insights into the limitations of UV-C lamps in real-world conditions and highlight the need for more effective disinfection strategies in hospitals.


Asunto(s)
Escherichia coli , Rayos Ultravioleta , Desinfección/métodos
13.
Huan Jing Ke Xue ; 45(3): 1561-1576, 2024 Mar 08.
Artículo en Chino | MEDLINE | ID: mdl-38471870

RESUMEN

At the time when water resources are in short supply,wastewater recycling is both an important environmental protection strategy and also a resource strategy. Disinfection is essential to ensure the biological safety of reclaimed wastewater by killing pathogens and preventing the spread of waterborne diseases. However,the disinfection process could inevitably produce toxic disinfection byproducts(DBPs)due to the reaction between the disinfectants and wastewater organic matters. Regarding wastewater DBPs,this study reviewed their identification methods,formation conditions(including precursors,the effect of water quality,disinfectants,and operational parameters on DBPs),and control methods(including source control,process control,and end control). In addition,future research trends of wastewater DBPs were discussed.


Asunto(s)
Desinfectantes , Contaminantes Químicos del Agua , Purificación del Agua , Desinfección/métodos , Aguas Residuales , Purificación del Agua/métodos , Contaminantes Químicos del Agua/análisis , Halogenación
14.
Environ Sci Pollut Res Int ; 31(18): 26592-26605, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451458

RESUMEN

A lab-scale reactor with a fixed-bed hematite catalyst for the effective decomposition of H2O2 and bacteria inactivation was designed. The bactericidal effect is the largest at a low initial bacterial count of 2·103 CFU/L, which is typical for natural surface waters. When using a 5 mM H2O2 solution and a residence time of 104 min, the reduction in the number of E. coli bacteria is about 3.5-log. At a higher initial bacterial count of 1-2·104 CFU/L, a 5 mM H2O2 solution reduces the bacteria number by about 4-log. The H2O2 decomposition follows the log-linear kinetics of a first-order reaction while the bacterial inactivation does not. The kinetics of bacterial inactivation was described using the Weibull model in the modified form: log10(N0/N) = b · tn. The values of the non-linearity parameter n were found to be lower than 1, indicating that bacterial inactivation slows down over time. With increasing initial H2O2 concentration, the rate parameter b increases while the non-linearity parameter n decreases. With increasing temperature, both parameters increase. The stability of the catalyst has been proved by XRD, FTIR, SEM, and ICP-OES. The concentration of iron leaching into water during disinfection is much lower than the limit declared by WHO for iron in drinking water. The results show that technical-grade hematite is a promising Fenton-like catalyst for water disinfection. The fixed-bed reactor can be the basis of the mobile installations for water purification in emergencies.


Asunto(s)
Desinfección , Compuestos Férricos , Peróxido de Hidrógeno , Purificación del Agua , Peróxido de Hidrógeno/química , Desinfección/métodos , Cinética , Purificación del Agua/métodos , Catálisis , Compuestos Férricos/química , Escherichia coli/efectos de los fármacos
15.
Talanta ; 273: 125901, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38503122

RESUMEN

Aromatic disinfection by-products (DBPs) have garnered considerable interest in recent years for their potential carcinogenicity. However, efficient separation and enrichment of DBPs in complex samples is a challenge due to the extremely low content of aromatic DBPs and the complexity of sample matrices. In this study, a MIL-101(Cr)-NH2@TAPB-DVA-COF hybrid material was prepared as the enrichment medium of membrane solid-phase extraction (M-SPE) to efficiently determine trace emerging aromatic DBPs. This medium exhibited excellent enrichment capacity and selectivity for aromatic DBPs because of the strong hydrogen bonding, π-π stacking and hydrophobic interactions. An efficient analytical method for five aromatic DBPs in juice drinks was successfully established by use of this hybrid material as the enrichment medium for M-SPE in combination with liquid chromatography tandem mass spectrometry (LC-MS/MS). The limits of detection of the established method were from 0.50 to 3.00 ng/L. Moreover, the method had been successfully used in real juice drinks to determine trace five aromatic DBPs with the spiked recoveries ranging from 84.1% to 125%. The method possessed high analytical sensitivity and accuracy for these five aromatic DBPs in juice drinks with the aid of the efficient M-SPE technology proposed.


Asunto(s)
Benzamidinas , Desinfección , Estructuras Metalorgánicas , Espectrometría de Masas en Tándem , Cromatografía Liquida , Desinfección/métodos , Espectrometría de Masas en Tándem/métodos , Extracción en Fase Sólida/métodos , Cromatografía Líquida de Alta Presión/métodos
16.
Water Res ; 254: 121339, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432003

RESUMEN

Loose deposit particles in drinking water distribution system commonly exist as mixtures of metal oxides, organic materials, bacteria, and extracellular secretions. In addition to their turbidity-causing effects, the hazards of such particles in drinking water are rarely recognized. In this study, we found that trace per- and polyfluoroalkyl substances (PFASs) could dramatically promote the formation of disinfection byproducts (DBPs) by triggering the release of particle-bound organic matter. Carboxylic PFASs have a greater ability to increase chloroacetic acid than sulfonic PFASs, and PFASs with longer chains have a greater ability to increase trichloromethane release than shorter-chain PFASs. Characterization by organic carbon and organic nitrogen detectors and Fourier transform ion cyclotron resonance mass spectrometry revealed that the released organic matter was mainly composed of proteins, carbohydrates, lignin, and condensed aromatic structures, which are the main precursors for the formation of DBPs, particularly highly toxic aromatic DBPs. After the release of organic matter, the particles exhibit a decrease in surface functional groups, an increase in surface roughness, and a decrease in particle size. The findings provide new insights into the risks of loose deposits and PFASs in drinking water, not only on PFASs per se but also on its effect of increasing toxic DBPs.


Asunto(s)
Desinfectantes , Agua Potable , Fluorocarburos , Contaminantes Químicos del Agua , Purificación del Agua , Desinfección/métodos , Desinfectantes/análisis , Agua Potable/análisis , Purificación del Agua/métodos , Halogenación , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis
17.
Water Res ; 254: 121386, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38457942

RESUMEN

Traditional disinfection processes face significant challenges such as health and ecological risks associated with disinfection-residual-bacteria due to their single mechanism of action. Development of new disinfection processes with composite mechanisms is therefore urgently needed. In this study, we employed liquid ground-electrode dielectric barrier discharge (lgDBD) to achieve synergistic sterilization through electric field electroporation and reactive species oxidation. At a voltage of 12 kV, Pseudomonas fluorescens (ultraviolet and ozone-resistant) and Bacillus subtilis (chlorine-resistant) were completely inactivated within 8 and 6 min, respectively, surpassing a 7.0-log reduction. The lgDBD process showed good disinfection performance across a wide range of pH values and different practical water samples. Staining experiments suggest that cellular membrane damage contributes to this inactivation. In addition, we used a two-dimensional parallel streamer solver with kinetics code to fashion a representative model of the basic discharge unit, and discovered the presence of a persistent electric field during the discharge process with a peak value of 2.86 × 106 V/m. Plasma discharge generates excited state species such as O(1D) and N2(C3Πu), and further forms reactive oxygen and nitrogen species at the gas-liquid interface. The physical process, which is driven by electric field-induced cell membrane electroporation, synergizes with the bactericidal effects of reactive oxygen and nitrogen species to provide effective disinfection. Adopting the lgDBD process enhances sterilization efficiency and adaptability, underscoring its potential to revolutionize physicochemical synergistic disinfection practices.


Asunto(s)
Ozono , Purificación del Agua , Desinfección/métodos , Bacterias , Cloro , Nitrógeno , Purificación del Agua/métodos
18.
Water Res ; 254: 121409, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38461602

RESUMEN

Chloramine is the second most popular disinfectant and is widely used in the disinfection of drinking water. For chloramine disinfection, some standards require the total chlorine concentration to be maintained in an appropriate range in the water distribution system. Therefore, exploring the mechanism of chloramine decay and deriving an accurate chloramine decay model helps to optimize the disinfection process and ensure water quality safety. This paper proposed a locally enhanced mixed-order(LEM) model consisting of the first order model and the mixed order model to describe chloramine auto-decomposition and decays caused by other reactions respectively. Via proving the parameter a and k2 related to temperatures instead of initial chloramine concentration, the model had been further simplified. Nine chloramine decay experiments with different initial chloramine concentrations and temperatures were designed and carried out to evaluate the new model performance for chloramine decay simulation. The research results showed that the simplified LEM model could simulate the whole process of chloramine decay well. Its accuracy evaluation indexes (R2 and SSE) were better than that obtained from the first order model and the mixed order model. This paper proposed a simple and accurate method to simulate the process of chloramine decay and had a guiding significance for water quality safety assurance.


Asunto(s)
Desinfectantes , Agua Potable , Purificación del Agua , Cloraminas , Desinfección/métodos , Purificación del Agua/métodos , Cloro
19.
Water Res ; 254: 121432, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38461606

RESUMEN

Chloramination is an effective strategy for eliminating pathogens from drinking water and repressing their regrowth in water distribution systems. However, the inevitable release of NH4+ potentially promotes nitrification and associated ammonia-oxidizing bacteria (AOB) contamination. In this study, AOB (Nitrosomona eutropha) were isolated from environmental water and treated with two disinfection stages (chloramine disinfection and chloramine residues) to investigate the occurrence mechanisms of AOB in chloramination. The results showed that N. eutropha had considerable resistance to monochloramine compared to Escherichia coli, whose inactivation rate constant was 19.4-fold lower. The higher resistance was attributed to high levels of extracellular polymer substances (EPS) in AOB, which contribute to AOB surviving disinfection and entering the distribution system. In AOB response to the chloramine residues stage, the respiratory activity of N. eutropha remained at a high level after three days of continuous exposure to high chloramine residue concentrations (0.5-1.5 mg/L). Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) suggested that the mechanism of N. eutropha tolerance involved a significantly high expression of the intracellular oxidative stress-regulating (sodB, txrA) and protein-related (NE1545, NE1546) genes. Additionally, this process enhanced EPS secretion and promoted biofilm formation. Adhesion predictions based on the XDLVO theory corroborated the trend of biofilm formation. Overall, the naturally higher resistance contributed to the survival of AOB in primary disinfection; the enhanced antioxidant response of surviving N. eutropha accompanied by biofilm formation was responsible for their increased resistance to the residual chloramines.


Asunto(s)
Agua Potable , Purificación del Agua , Antioxidantes , Abastecimiento de Agua , Purificación del Agua/métodos , Cloraminas/química , Desinfección/métodos , Biopelículas , Amoníaco/metabolismo
20.
Water Res ; 254: 121441, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38479173

RESUMEN

This study examined the antimicrobial efficacy of peroxymonosulfate (PMS) against bacteria, using Escherichia coli (E. coli) as a model organism. Our investigation delineates the complex mechanisms exerted by unactivated PMS. Thus, an initial redox reaction between PMS and the target biomolecules of bacteria generates SO4•- as the pivotal reactive species for bacterial inactivation; to a lesser extent, •OH, 1O2, or O2•- may also participate. Damage generated during oxidation was identified using an array of biochemical techniques. Specifically, redox processes are promoted by PMS and SO4•- targets and disrupt various components of bacterial cells, predominantly causing extracellular damage as well as intracellular lesions. Among these, external events are the key to cell death. Finally, by employing gene knockout mutants, we uncovered the role of specific gene responses in the intracellular damage induced by radical pathways. The findings of this study not only expand the understanding of PMS-mediated bacterial inactivation but also explain the ten-fold higher effectiveness of PMS than that reported for H2O2. Hence, we provide clear evidence that unactivated PMS solutions generate SO4•- in the presence of bacteria, and consequently, should be considered an effective disinfection method.


Asunto(s)
Desinfección , Peróxido de Hidrógeno , Desinfección/métodos , Escherichia coli , Peróxidos/química , Oxidación-Reducción , Bacterias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...